Integrated intelligent multi-parameter differential pressure flow meter

  • Product Description
  • This instrument integrates the collection of differential pressure, pressure, and temperature signals with on-site data processing, and is an intelligent multi-parameter flow detection device. It can be matched with throttling devices (standard orifice plates, annular orifice plates, nozzles, Venturi tubes, V-shaped inner cones) to form an integrated intelligent flow meter, used for measuring the volumetric flow of various liquids, gases, and steam, as well as standard volumetric flow and mass flow.The instrument uses a high-performance microprocessor chip to collect flow, temperature, and pressure signals. The signals are amplified, non-linearly corrected, and calculated for coefficients, allowing for real-time display of instantaneous and cumulative flow, as well as the temperature and pressure of the medium. Flow signals can be output in unit pulses, (4-20)mA, or RS485.

    Main features of the instrument:

    Precision die-cast aluminum alloy housing, IP65 protection level, suitable for outdoor installation;

    Simultaneously has explosion-proof and intrinsic safety explosion-proof performance;

    Large screen with backlight LCD, clear display, can show instantaneous flow, cumulative flow, temperature, and pressure values of the medium;

    Has automatic compensation function for the temperature and pressure of the medium, with real-time sampling of temperature and pressure values, which can also be set manually;

    5-segment instrument coefficient, automatic non-linear correction;

    Display of instantaneous flow units, volumetric flow under working conditions, standard volumetric flow, and mass flow units can be selected by the user;

    Configurable cut-off for any small flow signal;

    Parameters and flow values set internally can be permanently saved during power outages;

    High accuracy, good repeatability, and high reliability.

    Main technical parameters:

    Differential pressure measurement range: (0-6-250) kPa for each range;

    Temperature measurement range: (-20-400)℃ with segments (or according to order requirements)

    Pressure measurement range: (0-25) MPa with segments (or according to order requirements)

    Power supply: rated 24VDC (variation range (11.5-30)VDC)

    Flow system testing accuracy:

    a. Actual flow calibration: ±0.5%

    b. Theoretical calculation:

    1) Standard orifice plate: ±1.5%

    2) Other throttling devices: determined by the accuracy of the throttling element

    Maximum cumulative flow display: 9999999999

    Output

    a: Unit pulse: 100/liter, 10/liter, 1/liter (user configurable)

    b: (4-20)mA (corresponding to minimum to maximum instantaneous volumetric flow)

    c: RS485; Modbus protocol, output instantaneous flow, cumulative flow, medium temperature, pressure values (protocol provided)

    Medium temperature

    a: Non-explosion-proof type ≤400℃

    b: Explosion-proof type, should comply with the provisions in GB3836.1-2000

    Working environment

    a: Temperature: (-20-50)℃

    b: Relative humidity: ≤90%

    c: Explosion-proof performance: Explosion-proof: ExdⅡBT4-T6; Intrinsic safety explosion-proof: ExiaⅡCT4-T6

    Power-off data retention time: >3 years

    Maximum power consumption: 0.2W