1. Simple structure, easy installation, accurate measurement, no need for actual flow calibration. 2. Low manufacturing cost, wide range of applications. 3. Corner pressure tapping, flange pressure tapping, radial pressure tapping. 4. Moderate accuracy, accuracy level 0.5~1.5. 5. Can measure the flow of gas, liquid, and steam, with a wide range of adaptability. 6. Nominal diameter: DN50~DN1000 (orders exceeding this range can be negotiated)

View Details +

By adopting an equal pressure ring structure, the sources of measurement errors are reduced. The average static pressure of the pressure tapping cross-section upstream and downstream on the flow meter plate is introduced to the differential pressure transmitter, which weakens the influence of the velocity distribution distortion caused by the local resistance upstream on the accuracy, and the actual accuracy is closer to the basic accuracy.

View Details +

Integrate a flow restriction device (standard orifice plate, nozzle, annular orifice plate, etc.) with a differential pressure transmitter.

View Details +

High accuracy, outflow coefficient uncertainty ±0.7%~±1.5%

View Details +

1. For rectangular duct airflow measurement 2. Easy installation, compact structure, and low maintenance 3. Low pressure loss, energy saving 4. Inlet equivalent diameter: D=1.13(WH)0.5≤1200mm 5. Accuracy level: 2.5 ~5.0

View Details +

An insertion Venturi tube is a classic Venturi tube or double Venturi tube with a small diameter inserted into a circular pipeline. By measuring the flow rate of the inserted tube, the flow rate of the entire pipeline can be obtained. It can be used in the flow measurement of larger diameter gases (such as coal gas and flue gas).

View Details +

Measuring high-viscosity media, suitable for liquid-solid mixtures containing suspended particles

View Details +

Accuracy levels: 1.0, 1.5, 0.5 (requires actual flow calibration); Repeatability: 0.1%; Measurement range ratio up to 15:1.

View Details +

1. Robust structure, stable performance, high temperature resistance, and long lifespan; 2. High measurement accuracy, 1/4 of that of ordinary nozzles; 3. Straight-through pipeline, not easily blocked; 4. Pressure tapping method: throat pressure tapping; 5. Nominal diameter: DN(100~600); 6. β value range: 0.25~0.5; 7. Shorter straight pipe section requirement: 20D0 before, 10D0 after (Note: D0 is the actual inner diameter of the process pipeline); 8. Measurable fluid Reynolds number (Red) range: ≥1×106.

View Details +

1. Robust structure, reliable and durable, long lifespan, and corrosion-resistant. 2. Compared to orifice plates, it has low pressure loss and saves energy. 3. No flow calibration required. 4. Pressure tapping method: Corner tapping. 5. High accuracy, flow coefficient uncertainty is 0.8%~1.2%. 6. High temperature and high pressure resistant, stable performance, and long service life. 7. Nominal diameter: DN50-DN500

View Details +

Strong ability to resist upstream interference, and is not affected by downstream fluid parameters. It operates stably and can be calibrated on-site using actual gas (natural gas).

View Details +

The straight pipe segment is short, with a length of 0.6D0 for the front straight pipe segment and 0.2D0 for the rear straight pipe segment (Note: D0 is the actual inner diameter of the process pipe)

View Details +

< 12 >