XSL intelligent traffic display

This instrument uses a high-performance microprocessor chip to collect flow, temperature, and pressure signals. After signal amplification, non-linear correction, and coefficient calculation, the instantaneous and cumulative flow rate, as well as temperature and pressure, are displayed. The flow signal can be output in unit pulse, (4~20)mA, and RS485 modes.
  • Product Description
  • This instrument uses a high-performance microprocessor chip to collect flow, temperature, and pressure signals. After signal amplification, non-linear correction, and coefficient calculation, the instantaneous and cumulative flow rate, as well as temperature and pressure, are displayed. Flow signals can be output in unit pulse, (4~20)mA, and RS485 modes. It can be used with various flow meters for the measurement of working volume flow, standard volume flow, and mass flow of various liquids, gases, and steam.

    Main Features:

    5-segment instrument coefficient, automatic non-linear correction;

    Any small flow signal can be set for exclusion;

    Automatic compensation for the temperature and pressure of the medium;

    Internal settings and flow values are permanently saved during power failure.

    With a backlit LCD screen, it can simultaneously display the instantaneous and cumulative flow rate of the medium;

    Working volume flow, standard volume flow, and mass flow display can be selected;

    High accuracy, good repeatability, high reliability;

    Main Technical Parameters

    1. Flow Input Signal:

    a Pulse: (1~5000)Hz; Low level <1V, High level >2.5

    b Analog: (4~20)mA

    c Digital: HART (customized), RS485 (Modbus protocol)

    Temperature Input Signal: 4~20mA、Pt100

    Pressure Compensation Range: 4~20mA

    2. Power Supply:

    a: 24VDC (variation range (11.5~30)VDC)

    b: 220VAC ±10% 50Hz

    3. Accuracy:

    Flow: Pulse signal: ±1 error per 10000 flow pulses;

    (4~20)mA: ±0.2%

    Temperature: ±0.5%

    Pressure: ±0.5%

    4. Maximum Cumulative Flow Display:9999999999

    5. Output (configured according to order requirements):

    a: Unit pulse: 100/liter, 10/liter, 1/liter

    b: (4~20)mA (corresponding to minimum to maximum instantaneous volume flow)

    c: RS485 (Modbus protocol, output instantaneous, cumulative flow, medium temperature, pressure)

    Printer Interface: 15-pin parallel port (configured according to order requirements)

    Power Output: 24VDC/80mA

    6. Operating Environment

    a: Temperature: (0~40)℃

    b: Relative Humidity: ≤90%

    Power-off data retention time: >3 years

    Maximum power consumption: 1W

    External dimensions and aperture size: Type B 160×80×150 (width × height × depth); Aperture size: 152×76

Key words: